Signal processing of virtual-neutral to ground voltage for power control in electric arc furnaces Academic Article in Scopus uri icon

abstract

  • This research work proposes to detect arc conditions of electric arc furnaces (EAFs) based upon digital signal processing of the line to ground three-phase voltage measurements at the secondary side of the furnace transformer. It uses the voltage difference between a virtual-neutral point of the symmetrical power source and the furnace shell ground voltage. For harmonic analysis this voltage is processed using Fourier transform. The obtained information is found to be useful to detect arc operational conditions like arc stability, arc balance, and arc slag coverage. With the here in proposed arc indicators, the power control of the EAF can be performed using the concept of a dynamic power profile to set the operational transformer tap and current set points of the EAF control systems. The time and frequency domain analysis of the voltage difference between a virtual-neutral, from the delta connected transformer, to the furnace shell ground voltage, showed relevant information of the heat process like arc stability, arc slag coverage, and electrical circuit imbalance. The proposed arc indexes can be considered as process variables to improve the power control of Electric Arc Furnaces. Copyright © 2014 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

publication date

  • February 1, 2014