Silicon Photomultipliers for Determining Position of Microfluidic Radioactive Samples Academic Article in Scopus uri icon

abstract

  • © 2018 IEEE.An on-chip sensing circuit for measuring radioactivity in different positions of a microfluidic device through the use of silicon photomultipliers (SiPM) is presented. It is intended for use in a microfluidic platform producing radiopharmaceuticals for PET imaging. The results show that an array of SiPMs can be used to determine the position of a radioactive sample within a microfluidic chip with enough precision to be usable.

publication date

  • December 31, 2018