Effects of External Resistance, New Electrode Material, and Catholyte Type on the Energy Generation and Performance of Dual-Chamber Microbial Fuel Cells
Academic Article in Scopus
Overview
Identity
Additional document info
View All
Overview
abstract
In this study, the effects of an external resistance, new electrode material, and non-conventional catholyte on the energy generation and performance of a dual-chamber MFC were evaluated. Ten different resistances (15 ¿¿220 k¿), hydrophilically-treated graphene and graphite electrodes, and a 0.1 M HCl solution as a catholyte were assessed. The results showed that greater energy generation and power density were achieved at an external resistance of 2 k¿ and internal resistance between 2 and 5 k¿ on average; meanwhile, the greatest coulombic efficiency was obtained at the lowest external resistance evaluated (15 ¿). Therefore, it is recommended to operate the MFCs at the external resistance between 2 and 5 k¿ to ensure the maximum power generation of the dual chamber MFCs. Regarding the two electrode materials evaluated as an anode and cathode, hydrophilically-treated graphene was found to be a much better material to enhance the energy production and performance of the MFC system; therefore, its use is suggested in experimental and practical applications. On the other hand, the use of HCl as a catholyte enhanced the performance of MFC (constant and steady potential and greater coulombic efficiency) in most cases. © 2023 by the authors.
status
publication date
published in
Identity
Digital Object Identifier (DOI)
Additional document info
has global citation frequency
volume